110 lines
2.7 KiB
C++
110 lines
2.7 KiB
C++
|
/* **************************************************************************
|
||
|
|
||
|
Author: Achim Gaedke
|
||
|
Created: June 2004
|
||
|
|
||
|
****************************************************************************/
|
||
|
#include "machines/hardware.h"
|
||
|
#include "core/core.h"
|
||
|
#include "drivers/PTS-Synthesizer/PTS.h"
|
||
|
#include "drivers/Spectrum-MI40xxSeries/Spectrum-MI40xxSeries.h"
|
||
|
#include "drivers/SpinCore-PulseBlaster24Bit/SpinCore-PulseBlaster24Bit.h"
|
||
|
|
||
|
/**
|
||
|
\defgroup mobilemachine Mobile NMR Spectrometer
|
||
|
\ingroup machines
|
||
|
Uses Spincore Pulseblaster 24 Bit and Spectrum MI4021, PTS310 with cable driver with phase control and no synchronization board
|
||
|
\li line 0 for gate
|
||
|
\li line 1 for pulse
|
||
|
\li llne 17 for trigger
|
||
|
\li line 16 free (not using synchronization board)
|
||
|
|
||
|
\par Starting the hardware
|
||
|
This procedure should assure the correct initialisation of the hardware:
|
||
|
\li Switch off main switches of SpinCore Pulseblaster and Computer (the main switch of the computer is at the rear)
|
||
|
\li Switch on Computer and start Windows or linux
|
||
|
|
||
|
@{
|
||
|
*/
|
||
|
|
||
|
/**
|
||
|
*/
|
||
|
class Mobile_hardware: public hardware
|
||
|
{
|
||
|
|
||
|
PTS* my_pts;
|
||
|
SpinCorePulseBlaster24Bit* my_pulseblaster;
|
||
|
SpectrumMI40xxSeries* my_adc;
|
||
|
|
||
|
public:
|
||
|
Mobile_hardware()
|
||
|
{
|
||
|
ttlout trigger;
|
||
|
trigger.id = 0;
|
||
|
/* trigger on line 17 */
|
||
|
trigger.ttls = 1 << 17;
|
||
|
my_adc = new SpectrumMI40xxSeries(trigger);
|
||
|
/* device_id=0, clock=100MHz, sync_mask: Bit 16 */
|
||
|
my_pulseblaster = new SpinCorePulseBlaster24Bit(0, 1e8, 0 << 16);
|
||
|
my_pts = new PTS_latched(0);
|
||
|
|
||
|
// publish devices
|
||
|
the_pg = my_pulseblaster;
|
||
|
the_adc = my_adc;
|
||
|
the_fg = my_pts;
|
||
|
}
|
||
|
|
||
|
virtual ~Mobile_hardware()
|
||
|
{
|
||
|
if (the_adc != NULL)
|
||
|
delete the_adc;
|
||
|
if (the_fg != NULL)
|
||
|
delete the_fg;
|
||
|
if (the_pg != NULL)
|
||
|
delete the_pg;
|
||
|
}
|
||
|
|
||
|
};
|
||
|
|
||
|
/**
|
||
|
\brief brings standard core together with the Mobile NMR hardware
|
||
|
*/
|
||
|
class Mobile_core: public core
|
||
|
{
|
||
|
std::string the_name;
|
||
|
public:
|
||
|
Mobile_core(const core_config& conf) :
|
||
|
core(conf)
|
||
|
{
|
||
|
the_hardware = new Mobile_hardware();
|
||
|
the_name = "Mobile backend without synchronisation card";
|
||
|
}
|
||
|
virtual const std::string& core_name() const
|
||
|
{
|
||
|
return the_name;
|
||
|
}
|
||
|
};
|
||
|
|
||
|
/**
|
||
|
@}
|
||
|
*/
|
||
|
|
||
|
int main(int argc, const char** argv)
|
||
|
{
|
||
|
int return_result = 0;
|
||
|
try
|
||
|
{
|
||
|
core_config my_conf(argv, argc);
|
||
|
// setup input and output
|
||
|
Mobile_core my_core(my_conf);
|
||
|
// start core application
|
||
|
my_core.run();
|
||
|
}
|
||
|
catch (const DamarisException& e)
|
||
|
{
|
||
|
fprintf(stderr, "%s\n", e.what());
|
||
|
return_result = 1;
|
||
|
}
|
||
|
return return_result;
|
||
|
}
|