damaris-backends/machines/pulseblaster_only.cpp

117 lines
2.8 KiB
C++
Raw Permalink Normal View History

2016-10-20 17:57:18 +00:00
/* **************************************************************************
Author: Markus Rosenstihl
Created: June 2016
****************************************************************************/
#include "machines/hardware.h"
#include "core/core.h"
#include "drivers/PTS-Synthesizer/PTS.h"
#include "drivers/Tecmag-DAC20/DAC20.h"
2016-10-20 17:57:18 +00:00
#include "drivers/dummy/dummy.h"
#include "drivers/SpinCore-PulseBlaster24Bit/SpinCore-PulseBlaster24Bit.h"
/**
\defgroup mobilemachine Mobile NMR Spectrometer
\ingroup machines
Uses Spincore Pulseblaster 24 Bit and Dummy ADC PTS310 with cable driver with phase control and no synchronization board
\li line 0 for gate
\li line 1 for pulse
\li llne 17 for trigger
\li line 16 free (not using synchronization board)
\par Starting the hardware
This procedure should assure the correct initialisation of the hardware:
\li Switch off main switches of SpinCore Pulseblaster and Computer (the main switch of the computer is at the rear)
\li Switch on Computer and start Windows or linux
@{
*/
/**
*/
class pulseblaster_only_hardware: public hardware
{
PTS* my_pts;
SpinCorePulseBlaster24Bit* my_pulseblaster;
dummy* my_adc;
DAC20* my_dac;
2016-10-20 17:57:18 +00:00
public:
pulseblaster_only_hardware()
{
//ttlout trigger;
//trigger.id = 0;
2016-10-20 17:57:18 +00:00
/* trigger on line 17 */
//trigger.ttls = 1 << 22;
2016-10-20 17:57:18 +00:00
my_adc = new dummy;
/* device_id=0, clock=100MHz, sync_mask: Bit 16 */
2016-10-27 15:20:25 +00:00
my_pulseblaster = new SpinCorePulseBlaster24Bit(0, 1e8);
2016-10-20 17:57:18 +00:00
my_pts = new PTS_latched(0);
my_dac = new DAC20(1);
my_dac->set_latch_bit(17); // 17 is default LE; DATA 18 and CLK 16
2016-10-20 17:57:18 +00:00
// publish devices
the_pg = my_pulseblaster;
the_adc = my_adc;
the_fg = my_pts;
list_dacs.push_back(my_dac);
2016-10-20 17:57:18 +00:00
}
virtual ~pulseblaster_only_hardware()
{
if (the_adc != NULL)
delete the_adc;
if (the_fg != NULL)
delete the_fg;
if (the_pg != NULL)
delete the_pg;
}
};
/**
\brief brings standard core together with the Mobile NMR hardware
*/
class pulseblaster_core: public core
{
std::string the_name;
public:
pulseblaster_core(const core_config& conf) :
core(conf)
{
the_hardware = new pulseblaster_only_hardware();
2016-10-27 15:20:25 +00:00
the_name = "pulseblaster backend without ADC card";
2016-10-20 17:57:18 +00:00
}
virtual const std::string& core_name() const
{
return the_name;
}
};
/**
@}
*/
int main(int argc, const char** argv)
{
int return_result = 0;
try
{
core_config my_conf(argv, argc);
// setup input and output
pulseblaster_core my_core(my_conf);
// start core application
my_core.run();
}
catch (const DamarisException& e)
{
fprintf(stderr, "%s\n", e.what());
return_result = 1;
}
return return_result;
}